RJ683X Multi-function safety tester,with AC withstand voltage, DC withstand voltage, insulation resistance test functions, for battery modules, pack, new energy vehicles, household appliances, power electronics and other industry products to provide fast and efficient safety combination testing.
nIt meets the test requirements of CCC, IEC, EN, VDE, BS,UL, JIS and other mandatory standards for electrical safety;
nAutomatic connection test of AC withstand voltage, DC withstand voltage and insulation resistance;
nArc detection, arc detection function, and output lock when the product test arc alarm is used to prevent irreparable damage caused by product burns caused by continuous arc discharge;
nDischarge function, DC withstand voltage or insulation resistance item test after the setting of discharge item, according to the capacitive size to set the discharge time, display the discharge process voltage, intuitive understanding of the discharge result;
n30 test groups, 8 test steps per group, easy to operate;
nRS232 interface, PLC interface.
Selection Guide
Function Model | AC withstand voltage (ACW) | DC withstand voltage (DCW) | Insulation (IR) |
RJ6836H | √ | √ | √ |
RJ6835H | √ | √ | √ |
RJ6833H | √ | √ | × |
Model | RJ6836H | RJ6835H | RJ6833H |
AC Withstand Voltage test | Output capacity | 500VA
(5000V/100mA) | 200VA
(5000V/40mA) |
Output voltage
Range/Resolution/Accuracy | 50V~5000V / 1V / ±(2% × display value + 5 words) |
Voltage frequency
Range/Accuracy | 50Hz / 60Hz / ±0.1% |
Lower current setting
Range | 0.00mA~99.99mA | 0.10mA~40.00mA |
Maximum current setting
Range | 0.10mA~99.99mA | 0.10mA~40.00mA |
Time settings
Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s / ±(0.2%× set value + 2 words) |
Current measurement
Range/Resolution/Accuracy | 0.10mA~99.99mA
0.01mA
±(2% × display value + 5 words) | 0.10mA~40.00mA
0.01mA
±(2% × display value + 5 words) |
DC Withstand Voltage test | Output capacity | 60VA(6000V/10mA) |
Output voltage
Range/Resolution/Accuracy | 50V~6000Vdc / 1V / ±(3% × display value + 10 words) |
Lower current setting
Range | 0mA~9.999mA |
Maximum current setting
Range | 0mA~9.999mA |
Time settings
Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s/ ±(0.2%× set value + 2 words) |
Current measurement
Range/Accuracy | 0mA~9.999mA / ±(2%× display value + 0.2%× range (20 words)) |
Insulation Resistance test | Output voltage
Range/Resolution/Accuracy | 25V~1000V / 1V / ±(2% × display value + 5 words) |
|
Lower resistor setting
Range | 0.3MΩ~99.9MΩ, 100MΩ-50000MΩ |
|
Maximum resistance setting
Range | 0~50000MΩ |
|
Time settings
Range/Resolution/Accuracy | 1.0s~999.9s / 0.1s / ±(0.2%× set value + 2 words) |
|
Resistance measurement
Range/Accuracy | 25V-199V:
0.3M-99.9M 3% × display value + 3 words
100-500M 5% × display value + 5 words
200V-299V:
0.3M-99.9M-199M 3% × display value + 3 words
200M-4999M 8% × display value + 2 words
300V-1000V:
0.3M-99.9M-199M 2% × display value + 3 words
200M-4999M 5% × display value + 5 words
5000M-9999M 8% × display value + 2 words
10000M-50000M 15% × display value + 30 words |
|
Other indicators | External interface | RS232, PLC |
Usage environment | 0℃~40℃/20%RH~70%RH |
Power supply | AC220V, 50Hz |
Weight | 17.5kg |
Exterior dimensions | 342mm×133mm×460mm (W×H×D),machine leg not included,the height of the machine leg is 15mm |