RJ6815D Potential Equalization Tester is a high-performance instrument for potential equalization testing of electrical products. It meets the testing requirements of IEC61851- Conductive Charging System for Electric Vehicles, UL1703- Flat Plate Solar Module Safety Certification Standard, and complies with various national testing standards and corresponding calibration regulations.
Its excellent performance and rich functions and external interfaces make it especially suitable for testing the grounding on-resistance of DC-powered electrical equipment, such as electric vehicles, charging piles, photovoltaic modules, household electrical appliances, electric tools, electric control and distribution equipment, medical electrical equipment, audio and video equipment, and so on.
l DC output, current output up to 50A;
l Four-wire compensation test to compensate for harness and contact resistance;
l Protection function, designed with hardware and software protection measures. When in overload and open circuit and other abnormal state, it will automatically stop the output and send an alarm signal;
l Adopt phase-shift full-bridge soft-switching conversion technology and the output current is stable and reliable;
l Standardly equipped with RS232 communication and PLC remote control ports to realize the automation data acquisition and remote contro
Function | Technical specifications |
Output Characteristics | Output current | Range/Resolution/Accuracy | DC 5.0A~50.0A / 0.1A / ±(0.5%rdg.+0.5%f.s.) |
Open circuit voltage | DC 10V |
Output Capacity | 1500VA |
Parameter setting | Resistance limit setting | Range/Resolution | 1mΩ~600mΩ / 1mΩ |
Lower resistance limit setting | Range/Resolution | 0mΩ~600mΩ / 1mΩ |
Time setting | Range/Resolution | 1.0s~999.9s / 0.1s |
Parameter Measurement | Current Measurement | Range/Resolution/Accuracy | DC 5.0A~50.0A / 0.1A / ±(0.5%rdg.+0.5f.s.) |
Voltage measurement | Range/Resolution/Accuracy | 0.00V~10.00V / 0.01V / ±(0.5%rdg.+0.5%f.s.) |
Resistance Measurement | Range/Resolution/Accuracy | 1mΩ~600mΩ / 1mΩ / ±(3%rdg.+2dgt.) |
Other indicators | External Interfaces | Standard: RS232; (Optional: LAN interface, RS485) |
Operating Environment | 0℃~40℃,20%RH~70%RH |
Power Supply | AC220V,50/60Hz,600VA |
Weight | 17.3kg |
External Dimension | 441mm×88mm×630mm(W×H×D), feet height: 15mm |
Attachment | 1 instruction manual, 1 power cord (1.5 meters), 1 communication cable (1.5 meters) |