Home>Products>Electrical Safety Analyzer>RJ6000 Safety Comprehensive Test System

RJ6000 Safety Comprehensive Test System

Product introduction Main Features Technical Specifications Download

RJ6000 safety comprehensive test system is an integrally designed safety test system and it meets the needs of electrical production safety testing, with data storage, query function, to provide data traceability for the product.


Safety Performance Comprehensive Tester: Grounding, insulation, Voltage withstand, leakage safety test, voltage, current, power electrical parameter test;

Programmable variable frequency power supply: Provide working power supply for the product under test;

All-in-one computer: Setting, displaying, storing and querying test data.


Tester and computer communication, query mode and control mode, so that the test data is controlled by different modes of uploading. Meet the needs of different test methods of customers;

All-in-one computer, the cabinet is the desktop, and it can meet the demand for small space placement;

Barcode scanning, accurately store and trace each product test data;

Test data report format can be customized according to customer needs.


Function


Technical specifications

Ground

resistance test

Open circuit output voltage

<12V

Output Current Setting

Range/Resolution/Accuracy

3A~30A/1A/±(3%rdg.+0.1A)

Current Frequency Setting

Range/Accuracy

50Hz/60Hz/±0.1%

Resistance limit setting

Range/Resolution

3A~10A:1mΩ~600mΩ/1mΩ

11A~25A:1mΩ~300mΩ/1mΩ

26A~30A:1mΩ~200mΩ/1mΩ

Lower resistance limit setting

Range/Resolution

0MΩ~100mΩ/1MΩ

Time setting

Range/Resolution/Accuracy

1.0s~999.9s/0.1s/±(1%st.+2dgt.)

Resistance Measurement

Range/Resolution/Accuracy

1MΩ~600mΩ/1mΩ/±(3%rdg.+5dgt.)

Insulation

Resistance Test

Up

2VA(1000V/2mA)

Output Voltage

Range/Resolution/Accuracy

200V~1000V/1V/±(3%rdg.+3dgt.)

Lower resistance limit setting

Range/Resolution

0.3MΩ~99.9MΩ/100MΩ~2000MΩ/0.1MΩ/1MΩ

Resistance limit setting

Range/Resolution

0.0MΩ~99.9MΩ/100MΩ~2000MΩ/0.1MΩ/1MΩ

Time setting

Range/Resolution/Accuracy

1.0s~999.9s/0.1s/±(1%st.+2dgt.)

Resistance Measurement

Range/Resolution/Accuracy

1.0MΩ~99.9MΩ/0.1MΩ/±(3%rdg.+3dgt.)

100MΩ~2000MΩ/1MΩ/±(8%rdg.+8dgt)

AC Voltage

Withstand Test

Output Capacity

100VA

Output Voltage

Range/Resolution/Accuracy

300V~5000V/1V/±(3%rdg.+10dgt.)

Voltage

Range/Accuracy

50Hz/60Hz/±0.1%

Current lower limit setting

Range/Resolution

0.00mA~20.00mA/0.01mA

Current Upper Limit Setting

Range/Resolution

0.10mA~20.00mA/0.01mA

Time setting

Range/Resolution/Accuracy

1.0s~999.9s/0.1s/±(1%st.+2dgt.)

Current Measurement

Range/Resolution/Accuracy

0.10mA~20.00mA/0.01mA/±(3%rdg.+3dgt.)

DC  voltage

withstand test

Output Capacity

40VA

Voltage

Range/Resolution/Accuracy

300V~4000V/1V/±(3%rdg.+20dgt.)

Current lower limit setting

Range/Resolution

0.000mA~9.999mA/0.001mA

Current Upper Limit Setting

Range/Resolution

0.100mA~9.999mA/0.001mA

Time setting

Range/Resolution/Accuracy

1.0s~999.9s10.1s/± (1%st.+2dgt.)

Current Measurement

Range/Resolution/Accuracy

0.010mA~9.999mA/0.001mA/±(3%rdg.+5dgt.)

Leakage

current test

Current lower limit setting

Range/Resolution

0μA~9999μA/1μA

Current lower limit setting

Range/Resolution

50μA~9999μA/1μA

Time setting

Range/Resolution/Accuracy

2.0s~999.9s/0.1s/±(1%st.+2dgt.)

Voltage measurement

Range/Resolution/Accuracy

60V~280V/1V/±(0.5%rdg.+2dgt.)

Current Measurement

Range/Resolution/Accuracy

50μA~9999μA/1μA/

DC~10kHz:±(3%rdg.+10dgt.)

10kHz~1MHz:± (5%rdg.+50dgt.)

Start-up

test

Current   upper   and   lower   limit

settings

Range/Resolution

0.00A~25.00A/0.01A

Time setting

Range/Resolution/Accuracy

1.0s~999.9s/0.1s/± (1%st.+2dgt.)

Voltage measurement

Range/Resolution/Accuracy

60V~280V/1V/±(0.5%rdg.+2dgt.)

Current Measurement

Range/Resolution/Accuracy

0.030A~3.999A/0.001A/± (0.5%rdg.+20dgt.)

4.00A~25.00A/0.01A/± (0.5%rdg.+2dgt.)

Power Test

Power   upper   and    lower   limit

settings

Range/Resolution

0W~6000W/1W

Time setting

Range/Resolution/Accuracy

1.0s~999.9s10.1s/± (1%st.+2dgt.)

Voltage measurement

Range/Resolution/Accuracy

60V~280V/1V/±(0.5%rdg.+2dgt.)

Current Measurement

Range/Resolution/Accuracy

0.030A~3.999A/0.001A/±(0.5%rdg.+20dgt.)

4.00A~25.00A/0.01A/±(0.5%rdg.+2dgt.)

Power Measurement

Range/Resolution/Accuracy

30.0W~199.9W/0.1W/± (0.5%rdg.+50dgt.)

200W~6000W/1W/± (0.5%rdg.+30dgt.)

Power Factor Measurement

Range/Resolution/Accuracy

0.10~1.00/0.01/±(2%rdg.+2dgt.)

Open     test

short

Open     test short circuit

Resistance  upper  and  lower  limit

settings

Range/Resolution

1Ω~500Ω/1Ω 

Time setting

Range/Resolution/Accuracy

1.0s~999.9s/0.1s/±(1%st.+2dgt.)

Resistance Measurement

Range/Resolution/Accuracy

12~500Ω/1Ω/± (2%rdg.+2dgt.)

Other

indicators

External Interfaces

RS232, PLC, power supply communication interface, alarm light interface

Operating Environment

0℃~40℃,20%RH~70%RH

Power Supply

AC220V,50/60Hz

External Dimension

800mm×800mm×670mm(W×H×D) excluding  the feet


Customer site

Products

Ruijie Instrument

Factory Address: No.38 Longfei Road, Chengyang District, Qingdao, China

4008-515-616

< a href="https://www.ruijie-ate.com/">在线客服