RJ683X AC/DC Voltage Withstand and Insulation Tester, has the test functions of AC Voltage withstand, DC Voltage withstand, insulation resistance and it can provide fast and efficient safety testing for battery modules, pack, new energy vehicles, household appliances, power electronics and other products.
l Meet the test requirements of CCC, IEC, EN, VDE, BS, UL, JIS and other mandatory standards for electrical safety;
l Automated articulation test for AC withstand voltage, DC withstand voltage, insulation resistance items;
l Arc detection, arc detection function, and output lockout when product testing arc alarms, so as to prevent irreparable damage caused by product burns from continuous arc discharge;
l Discharge function, DC withstand voltage or insulation resistance project after the test to set the discharge project, according to the size of the capacitance to set the discharge time, display the discharge process voltage, intuitive understanding of the discharge results;
l 30 test groups, 8 test steps per group, convenient operation;
l RS232 interface, PLC interface.
Model | Alternating current voltage withstand (ACW) | DC voltage withstand (DCW) | Insulation (IR) |
RJ6836H | √ | √ | √ |
RJ6835H | √ | √ | √ |
RJ6833H | √ | √ | × |
Model | RJ6836H | RJ6835H | RJ6833H |
AC Volt age With stand Test | Output Capacity | 500VA (5000V/100mA) | 200VA (5000V/40mA) |
Output Voltage | Range/Resolution/Ac curacy | 50V~5000V /1V / ±(2%rdg.+5dgt.) |
Voltage Frequency | Range/Accuracy | 50Hz / 60Hz/ ±0.1% |
Current lower limit setting | Range | 0.00mA~99.99mA | 0.00mA~40.00mA |
Current Upper Limit Setting | Range | 0.00mA~99.99mA | 0.00mA~40.00mA |
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s /0.1s/ ±(0.2%st.+2dgt.) |
Current Measurement | Range/Resolution/Ac curacy | 0.10mA~99.99mA 0.01mA ±(2%rdg.+5dgt.) | 0.10mA~40.00mA 0.01mA ±(2%rdg.+5dgt.) |
DC volta ge with stand test | Output Capacity |
| 60VA(6000V/10mA) |
Output Voltage | Range/Resolution/Ac curacy | 50V~6000Vdc /1V / ±(3%rdg.+10dgt.) |
Current lower limit setting | Range | 0.000mA~9.999mA |
Current Upper Limit Setting | Range | 0.000mA~9.999mA |
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s / 0.1s/ ±(0.2%st.+2dgt.) |
Current Measurement | Range/Accuracy | 0.000mA~9.999mA/±(2%rdg.+0.2%f.s.(20dgt.)) |
Insul ation Resistance Test | Output Voltage | Range/Resolution/Ac curacy | 25V~3000V/ 1V / ±(2%rdg.+5dgt.) |
|
Lower resistance limit setting | Range | 0.3MΩ~99.9MΩ/100MΩ-50000MΩ |
|
Resistance limit setting | Range | 0~50000MΩ |
|
Time setting | Range/Resolution/Ac curacy | 1.0s~999.9s/0.1s/ ±(0.2%st.+2dgt.) |
|
Resistance Measurement | Range/Accuracy | 25V-199V: 0.3M-99.9M 3%rdg.+3dgt. 100M-500M 5%rdg.+5dgt. 200V-299V: 0.3M-99.9M-199M 3%rdg.+3dgt. 200M-4999M 8%rdg.+2dgt. 300V-3000V: 1M-99.9M-199M 2%rdg.+3dgt. 200M-4999M 5%rdg.+5dgt. 5000M-9999M 8%rdg.+2dgt. 10000M-50000M 15%rdg.+30dgt. |
|
Other indicators | External Interfaces | RS232, PLC (Optional: RS485) |
Operating Environment | 0℃~40℃,20%RH~70%RH |
Power Supply | AC220V,50/60Hz |
Weight | 18kg |
External Dimension | 342mm×133mm×460mm(W×H x D) excluding the feet height, the feet height is15mm |
Accompanying documents and Accessories | 1 instruction manual, 1 power cable (1.5 m), 1 communication cable (1.5 m), 1 set of test cables (1.5 m) |