RJ1836H Multi-functional safety tester, has the test functions of AC voltage withstand, DC voltage withstand, insulation resistance, and it can provide fast and efficient safety testing for battery module, pack, new energy automotive, household appliances, power electronics and other industries.
l Meet the test requirements of CCC, IEC, EN, VDE, BS, UL, JIS and other mandatory standards for electrical safety;
l Automated articulation test for AC withstand voltage, DC withstand voltage, insulation resistance items;
l Arc detection, arc detection function, and output lockout when product testing arc alarms, so as to prevent irreparable damage caused by product burns from continuous arc discharge;
l Discharge function, DC withstand voltage or insulation resistance project after the test to set the discharge project, according to the size of the capacitance to set the discharge time, display the discharge process voltage, intuitive understanding of the discharge results;
l 30 test groups, 8 test steps per group, convenient operation;
l RS232 interface, PLC interface, network port communication(LAN).
Model | RJ1836H |
AC Volt age Wit hsta nd Test | Output Capacity | 550 VA (5000V/110mA) |
Output Voltage | Range/Resolution/ Accuracy | 50V-5000V / 1V / ±(1%rdg.+5dgt.) |
Voltage Frequency | Range/Accuracy | 50Hz / 60Hz ±0.1% |
Current lower limit setting | Range | 0.000mA-110.0mA |
Current Upper Limit Setting | Range | 0.000mA-110.0mA |
Time setting | Range/Resolution/ Accuracy | 1.0s -999.9s /0.1S /±(0.1%rdg.+5dgt.) |
Current Measurement | Range/Resolution/ Accuracy | 0.001mA-110.0 mA /0.001/ 0.01 /0.1 ±(1%rdg.+5dgt.) |
DC volt age with stan d test | Output Capacity | 120 VA (6000V/20mA) |
Output Voltage | Range/Resolution/ Accuracy | 25V-6000V / 1V / ±(1%rdg.+5dgt.) |
Current lower limit setting | Range | 0.0μA-9999μA/10.00mA-20.00mA |
Current Upper Limit Setting | Range | 1.0μA-9999μA/10.00mA-20.00mA |
Time setting | Range/Resolution/ Accuracy | 1.0s -999.9s /0.1S /±(0.1%rdg.+5dgt.) |
Current Measurement | Range/Resolution/ Accuracy | 0.1uA/ 1uA /0.01mA ±(1%rdg.+5dgt.) |
Maximum Capacitive Load | 1μF<1000V , 0.75μF<2KV , 0.5uF<3KV ,0.08μF < 4KV ,0.04μF < 5KV |
Insu latio n Resi stan ce Test | Output Capacity | 120 VA (6000V/20mA) |
Output Voltage | Range/Resolution/ Accuracy | 25V-6000V / 1V / ±(1%rdg.+5dgt.) |
Lower resistance limit setting | Range | 0.100MΩ-100.00GΩ |
Resistance limit setting | Range | 0.100MΩ-100.00GΩ ;HHHH 表示不判断上限 |
Time setting | Range/Resolution/ Accuracy | 1.0s -999.9s /0.1S /±(0.1%rdg.+5dgt.) |
Resistance Measurement | Range/Accuracy | 25V-99V 0.100MΩ -500 MΩ ±(15%rdg.+2dgt.) 100V-499V 0.100MΩ-2.000GΩ ±(5%rdg.+2dgt.) 500V-799V 1.000MΩ-999.9MΩ ±(2%rdg.+2dgt.) 1.000GΩ-9.999GΩ ±(5%rdg.+2dgt.) 10.00GΩ-50.00GΩ ±(15%rdg.+2dgt.) 800V-6000V 1.000MΩ-999.9MΩ ±(2%rdg.+2dgt.) 1.000GΩ-9.999GΩ ±(5%rdg.+2dgt.) 10.00GΩ-100.00GΩ ±(15%rdg.+2dgt.) |
Maximum Capacitive Load | 1μF<1000V , 0.75μF<2KV , 0.5μF<3KV ,0.08μF < 4KV ,0.04μF < 5KV |
Othe r indi cato rs | Arc test | 0 off 1-9(1 most sensitive) |
External Interfaces | RS232,PLC LAN(Optional RS485) |
Operating Environment | 0℃~40℃,20%RH~70%RH |
Power supply interface | AC220V,50/60Hz |
Weight | 25kg |
External Dimension | 430mm×133mm×550mm(W×H×D) excluding the feet height, the feet height is15mm |
Accompanying documents and Accessories | 1 manual, 1 power cord (1.5 m), 1 set of communication cable (1.5 m), 1 set of test cable (1.5 m) |